Engine cooling water temperature

Ventilation/dehumidification — the silent 24/7 load, with heat recovery. Part of the glass family — like our glass BESS, biogas plant and CHP.

Engine cooling water temperature
Outdoor air Fresh air Heat recovery Heating coil Hall Exhaust
Glass-box in 4 steps

Understand → See it live → What the AI does → Your benefit

Step 1 of 4
1
Understand
2
See it live
3
What the AI does
Your benefit

What is engine cooling water temperature?

Engine cooling water is maintained at 85–92 °C (pressure 1.3–2.0 bar); if the temperature rises above the limit, the protective shutdown is triggered — too low reduces efficiency.

The plant — right now

connect… · anonymous reference plant · read-only from the process control system, calculated in-house Oil pressure … bar Oil temperature … °C Cooling water … °C Speed … 1/min Boost pressure … bar Engine room … °C Excerpt from … plant measurements. To the detailed explanation page with video →

What the AI reads from these values

What the AI reads
  • Monitoring of the temperature gradient for early detection of coolant losses
  • Comparison with the setpoint range (85–92 °C) to avoid an emergency shutdown
  • Detection of local hotspots in the block through deviations from the reference value
  • Verification of the efficiency, as temperatures that are too low reduce efficiency
Scenario

Monitored: continuous

The scenario: a gradual drop in oil pressure or a drifting temperature remains below the alarm threshold until the emergency shutdown occurs — at the worst possible moment. The AI: detects the deviation from normal operation early and reports it before the protection trips. It identifies the trend before the limit value is reached.

Why this matters

Stable operating temperatures prevent thermal stresses and avoid costly downtime caused by protective shutdowns. Maintaining the target temperature of approx. 83.4 °C (reference value) ensures the service life of the seals. Precise monitoring prevents efficiency loss due to a system that is too cool or overheated. electrical power (kW) · supplied gas power (kW) → — % elec. efficiency Calculation: electrical power ÷ gas power × 100