How are Lambda and NOx related?

Ventilation/dehumidification — the silent 24/7 load, with heat recovery. Part of the glass family — like our glass BESS, biogas plant and CHP.

How are Lambda and NOx related?
Outdoor air Fresh air Heat recovery Heating coil Hall Exhaust
Glass-box in 4 steps

Understand → See it live → What the AI does → Your benefit

Step 1 of 4
1
Understand
2
See it live
3
What the AI does
Your benefit

What is How are Lambda and NOx related??

Gas engines in lean operation (λ 1.5–1.7) produce less NOx than stoichiometric (λ 1.0); too low a Lambda increases NOx and the risk of knocking — the TecJet Lambda control (2G) maintains λ within the target corridor for optimal NOx compliance.

The plant — right now

connect… · anonymous reference plant · read-only from the process control system, calculated in-house Exhaust gas Cyl 1 … °C Before catalyst … °C After catalyst … °C Intake air … °C Excerpt from … plant measurements. To the detailed explanation page with video →

What the AI reads from these values

What the AI reads
  • Deviation from target Lambda: indicator for incorrect mixture composition and thus increasing NOx risk.
  • Trend of Lambda fluctuation: early warning of instabilities in the gas supply system or sensor drift.
  • Correlation of Lambda value and exhaust gas temperature: identification of hotspots that promote thermal NOx formation.
  • Compliance with the target corridor (e.g., 1.5–1.7): ensuring constant compliance with emission limit values.
Scenario

Monitored: continuous

The scenario: an emission value creeps slowly upwards, is only noticed during the official measurement, in the worst case resulting in operational restrictions. The AI: detects the trend towards the limit value early and reports a need for action before the measurement occurs. It identifies the trend before the limit value is exceeded.

Why this matters

Precise Lambda control minimises NOx concentration and prevents costly failures of the exhaust gas aftertreatment systems through stable operation. Stabilising the Lambda value within the target corridor reduces the thermal load on the components. This extends the service life of the catalyst and ensures compliance with statutory limit values. Measured value (mg/m³) · Limit value (mg/m³) → — % reserve to limit value Calculation: (Limit value − Measured value) ÷ Limit value × 100