The Glass CHP · Battery storage

Leak protection (coolant)

Ventilation/dehumidification — the silent 24/7 load, with heat recovery. Part of the glass family — like our glass BESS, biogas plant and CHP.

Leak protection (coolant)
Outdoor air Fresh air Heat recovery Heating coil Hall Exhaust
Glass-box in 4 steps

Understand → See it live → What the AI does → Your benefit

Step 1 of 4
1
Understand
2
See it live
3
What the AI does
Your benefit

What is coolant leak protection?

> Coolant leak protection in a battery storage system (BESS) is a critical safety function for monitoring thermal integrity. According to IEC 62933, the system ensures that the cooling medium remains within the closed circuit to protect the battery cells from overheating. A failure or defect leads directly to cell degradation and compromises the operational safety of the entire plant.

No own register — honestly

For this component, no own register is connected; therefore, no example value is provided here. Where the plant measures, the value is read as read-only and calculated internally. It is visible via connected components.

What the AI reads in this component

What the AI reads
  • Detection of a pressure drop in the cooling circuit as an indicator of pipe ruptures.
  • Monitoring of coolant level to ensure constant heat dissipation.
  • Early warning in case of local overheating due to insufficient circulation.
  • Documentation of system integrity for compliance with safety standards.
Scenario

Monitored: continuous

The scenario: > Monitoring: continuous · Gas, temperature, leak The scenario: a thermal runaway manifests as gases and an increase in temperature before it becomes visible. The AI: detects early signs and triggers in stages, rather than only at full fire. It identifies the trend before the limit value is reached.

Why it is important

A reliable leak protection system prevents thermal breakthroughs and thus secures the lifespan of the batteries and the long-term profitability of the BESS. Prevention of unplanned downtime through proactive maintenance of the cooling circuit. Reduction of insurance costs through verifiable compliance with technical safety standards. Warning time Gas→Aerosol (s) → — s Warning calculation: Time between gas warning and triggering

More pool worlds

Browse the 40 wizards

← PreviousFresh air▦ All 40
License the software

Bring the glass-box AI to your pool.

Stromfee.US licenses the pool & wellness HVAC AI — proven in Europe, deployed on your existing plant. Single property, portfolio or chain.

Request software license →
Standards & norms

What the rules require — Leak protection (coolant)

Grounded in the applicable national standards for battery energy storage systems. Same knowledge base as the European reference plant; presented anonymously.

Basis: the applicable national standards. Values shown are those measured on the plant, not target figures.