The Glass CHP · Battery storage

Gas alert / Aerosol detection

Ventilation/dehumidification — the silent 24/7 load, with heat recovery. Part of the glass family — like our glass BESS, biogas plant and CHP.

Gas alert / Aerosol detection
Outdoor air Fresh air Heat recovery Heating coil Hall Exhaust
Glass-box in 4 steps

Understand → See it live → What the AI does → Your benefit

Step 1 of 4
1
Understand
2
See it live
3
What the AI does
Your benefit

What is gas alert / aerosol detection?

> Gas warning and aerosol detection is a critical safety component in battery energy storage systems (BESS) to identify thermal runaway early. It detects the release of electrolyte gases or fire smoke particles before a chain reaction occurs. This monitoring is essential for maintaining the operating permit and preventing total failure of the battery modules.

No own register — honestly

For this component, no own register is linked; therefore, no example value is provided here. Where the system measures, the value is read as read-only and calculated in-house. It is visible via connected components.

What the AI reads in this component

What the AI reads
  • Electrolyte gas detection (e.g. H2, CO) as an indicator of cell damage
  • Aerosol detection to identify the development of a fire at an early stage
  • Ambient temperature monitoring to correlate with gas releases
  • Determination of the degree of localisation to initiate targeted extinguishing measures
Scenario

Monitored: continuous

The scenario: > Monitoring: continuous · Gas, temperature, leak The scenario: a thermal runaway manifests as gases and an increase in temperature before it becomes visible. The AI: detects the early signs and triggers in stages, rather than only at full fire. It identifies the trend before the limit value is reached.

Why it is important

Early detection prevents the destruction of entire battery modules and thus secures the long-term profitability of the system. Avoiding fire events reduces insurance premiums and prevents the loss of feed-in power. Precise monitoring according to VdS 3103 minimises the risk of production failures due to thermal instabilities. Warning time Gas→Aerosol (s) → — s Warning Calculation: Time between gas warning and triggering